3136/23Sub04

Status: Withdrawn (16 Sep 2024)
Application Details
Description

18. The following requirements of the Transportation Infrastructure Ireland shall be complied with g) Prior to commencement of development, a Construction Traffic Management Plan including access to services shall be submitted for the written agreement of the planning authority subject to the written agreement of TII. The Construction Traffic Management Plan shall identify mitigation measures to protect operational Luas infrastructure. h) Prior to commencement of development, a Demolition and/or Construction Method Statement shall be submitted for the written agreement of the planning authority subject to the written agreement of TII. The method statement shall resolve all Luas interface issues and shall (i) identify all Luas alignment interfaces, (ii) contain a risk assessment for works associated with the interfaces, and (iii) contain mitigation measures for unacceptably high risks, including vibration and settlement monitoring regime if necessary. The method statement shall be in accordance with TII’s 'Code of engineering practice for works on, near, or adjacent the Luas light rail system.' i) Overhead Conductor System (OCS) poles and / or fixings are located on / or adjacent to the proposed development. Prior to commencement of development, the following plans and details shall be submitted for the written agreement of the planning authority subject to the written agreement of TII: (a) OCS pole protection and safety distances, and / or (b) Existing, temporary and subsequent permanent fixings. The developer shall be liable for all costs associated with the removal and reinstatement of the Luas related infrastructure. j) The development shall ensure no risk of intrusion of people into the OCS danger zone via opening windows, maintenance, cleaning, balconies or terraces. The danger zone is described in TII's 'Code of engineering practice for works on, near, or adjacent the Luas light rail system' defined by a 2.75m offset in all directions from the nearest item of OCS infrastructure. k) Lighting design for the scheme shall not create glare onto the Luas alignment. Prior to commencement of development, details of lighting design shall be submitted for the written agreement of the planning authority subject to the written agreement of TII.

Council

Dublin New

Date Validated

14 Aug 2024

Decision Date

16 Sep 2024

Location
Address

1, Adelaide Road, Dublin 2, D02X889

Postcode

D02X889

Coordinates

53.332191793293006, -6.261357562148486

Source: Lat and Lng

Quick Info
UID
161346
Reference
3136/23Sub04
Status
Withdrawn
Last Updated
18 Sep 2024