LA06/2025/0741/DC
Application Details
Description
Discharge of Conditions 12 and 13 of LA06/2022/0881/F, in relation to plots 1 - 13 - Condition 12 - Prior to the occupation of the proposed development, a Verification Report shall be submitted to and agreed in writing by the Council. This report shall demonstrate the successful completion of remediation works and demonstrate that the site is now fit for end-use, including details of: a) Capping system • An appropriate capping system shall be installed within the garden and landscaped areas. A 600mm capping system is required in garden and landscaping areas with a minimum of 200mm crushed stone capillary break in the base overlain with 400mm of clean material above subsoil and topsoil. The report must include details of the methodology and programme of the capping system. • Photographs and records of any excavation works within the source area including photographs showing depths to accommodate the capping layer. • Records and photographs of the clean material being used and placed on the source area, also showing depths being placed. • Details of the materials that were used for the capping system along with laboratory certificates and results which confirm that the materials are suitable for use. b) Gas Protection measures • The measures must demonstrate compliance with the requirements of CS2 as prescribed in guidance within CIRIA C665 and attain a gas protection score of at least 3.5 with the report including. • Final designs of building gas protection measures • Details of any specific products used. • records from the installation process including photographic records of: • the installation of the under-floor void • the construction of the concrete floor • membrane installation works and • Records of inspection of installed gas protection measures Reason: Protection of human health Condition 13 - If during the development works, new contamination or risks are encountered which have not previously been identified, works shall cease and the Council shall be notified immediately. This new contamination shall be fully investigated in accordance with the Model Procedures for the Management of Land Contamination (CLR11). In the event of unacceptable risks being identified, a remediation strategy shall be agreed with the Council in writing, and subsequently implemented and verified to its satisfaction. Reason: To ensure that risks from land contamination to the future users of the land and neighbouring land are minimised, and to ensure that the development can be carried out safely without unacceptable risks to workers, neighbours and other offsite receptors.
Council
Ards North Down
Application Type
Discharge of Condition
Date Received
19 Aug 2025
Date Validated
19 Aug 2025
Decision Date
08 Oct 2025
Council Website
View on Ards North Down websiteLocation
Address
50 Main Street and lands to rear of 38-48 Main Street Carrowdore
Coordinates
54.575276010588212, -5.558061604332421
Source: Lat and Lng
Quick Info
- UID
- 701798
- Reference
- LA06/2025/0741/DC
- Status
- Granted
- Last Updated
- 15 Oct 2025